3.3

Canceling the commissioning mode

The commissioning mode can be immediately exited if no safety parameters were changed.
If safety parameters were changed, before exiting the commissioning mode, it still has to be
defined what should happen with the modified safety parameters.
Procedure
See also
Exit the commissioning mode (Page 52)
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
1.
You wish to cancel the commissioning mode.
Press the "Cancel" softkey.
Based on the checksums, the program checks as to whether SI parame‐
ters were changed.
If this is not the case, then the commissioning mode is exited at this point.
- OR -
If the program identifies that SI parameters were changed, then a prompt
is displayed as to what should happen with the modified data.
Objective: Confirm the changed data
2a.
Press the "OK" softkey to confirm the data of the actual drive and to exit
the commissioning mode. The actual checksum of the actual drive is
copied over to the reference checksum.
- OR -
Press the "Confirm all drives" softkey to confirm the data of all drives and
to exit the commissioning mode. The actual checksum of all drives is
copied over to the reference checksum.
This softkey is only visible if there are several drives in your drive system.
2b.
Objective: Undo changes
Press the "Reset (po)" softkey to undo all changes to the data. A POWER
ON reset is then carried out. You have the option to save the data if you
have changed it.
2c.
Objective: Remain in the commissioning mode
Press the "Cancel" softkey if you do not wish to exit the commissioning
mode.
The prompt is closed. The commissioning mode remains active.