Chapter 1 Operation Procedures
Operation Edition - 12
Turn the metering roller pressure adjustment knob
and adjust the aqua film thickness on the metering
roller.
Turn the metering roller pressure adjustment knob
in the "+"direction (counterclockwise) 10 pitches
more from the position that the aqua film is just cut
on the metering roller.
3) Set the water rider oscillating roller.
(1)
A
CAUTION
Stop the press before setting. Failure to follow this instruction may result in an
injury.
Turn the water rider oscillating roller release knob
(1)
and set at the 12 o'clock position.
When there is a unit which is not used, be sure to
turn the knob
(1)
and set at the 3 o'clock position
and pull the water rider oscillating roller by hand
toward you so that the water rider oscillating roller
is released from the water form roller.