2. Change of the cleaning of the compressor regulator element
I
Maintenance Edition -
371
21)
Cleaning the element of the compressor regulator
£WARNING
Mount the cover removed in place after cleaning. Failure to follow this instruction may result in a
serious injury.
«NOTICE»
Do not use organic solvents such as gasoline when cleaning the element.
The standard pressure of the regulator is 0.6 MPa. When the pressure is lower than 0.6 MPa, remove the element
of the regulator and clean it with the neutral detergent.
Cleaning procedures
1.
Remove the cover (1).
(1)
4. Tum the cover ( 1) and remove
it.
7. Mount the removed parts in the
reverse order.
(1)
(1)
2. Loosen the screw (1) to remove
3. Check the pressure gauge (1) to
all air.
be "0".
5. Turn the element holder
(1)
counterclockwise and remove
the element holder
(1)
and
element (2).
2
6. Clean the element by using the
neutral detergent.