Chapter 1 Operation Procedures
I•.Pre&s ¥fitt1Danipening SotutioniGir¢ulatioq . . .
pevice
I
4. Water Section Preparation
1) Prepare the dampening solution circulation device.
2) Set the metering roller.
UNIT
Make the dampening solution in which the alcohol
substitute with the proper density is added in
advance. Then pour it up to the line in the tank.
For the proper density of the alcohol substitute,
refer to the explanation of the alcohol substitute
used.
(Reference) The tank capacity is 13.4 liters of
dampening solution.
When the dampening solution in the
tank falls below the minimum level,
the buzzer will sound to inform the
operator.
Check that the water fountain dampening solution
level is high enough to soak the water fountain
roller. If not having enough dampening solution,
increase by using the water volume control valve.
When turning it counterclockwise, the volume
will be increased.
Shift the metering roller release lever in the direction
of the arrow ( ~ position) and contact the metering
roller with the water fountain roller.
Push the unit selection button for the unit to be used
to rotate the water fountain roller.
(Note) If there is no dampening solution in the water
fountain, the water sensor in the water
fountain will stop rotating the metering
roller. The paper feed also cannot be done.