13.Tumble Generator Valve
Actuator
A: REMOVAL
NOTE:
The tumble generator valve assembly of the STI
model cannot be disassembled.
1. RH SIDE
1) Release
the
fuel
FU(H4DOTC)-55, RELEASING OF FUEL PRES-
SURE, PROCEDURE, Fuel.>
2) Disconnect the ground cable from the battery.
3) Open the fuel filler flap lid, and remove the fuel
filler cap.
4) Remove
the
intake
FU(H4DOTC)-17, REMOVAL, Intake Manifold.>
5) Disconnect the connector from tumble generator
valve actuator.
6) Remove the tumble generator valve actuator.

Tumble Generator Valve Actuator

pressure.
<Ref.
to
FU-00009
manifold.
<Ref.
to
FU-00621
FU(H4DOTC)-43
FUEL INJECTION (FUEL SYSTEMS)
2. LH SIDE
1) Release
the
fuel
pressure.
FU(H4DOTC)-55, RELEASING OF FUEL PRES-
SURE, PROCEDURE, Fuel.>
2) Disconnect the ground cable from the battery.
3) Open the fuel filler flap lid, and remove the fuel
filler cap.
4) Remove the secondary air pump. <Ref. to
EC(H4DOTC)-9,
REMOVAL,
Pump.>
5) Disconnect the connector from tumble generator
valve actuator.
6) Remove the tumble generator valve actuator.
B: INSTALLATION
1. RH SIDE
Install in the reverse order of removal.
2. LH SIDE
Install in the reverse order of removal.
<Ref.
to
FU-00009
Secondary
Air
FU-00622