Absolute Position Parameters - Mitsubishi Electric MELDAS C6 Parameter Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

6.3 Absolute Position Parameters

#
Items
2049
type
Absolute
(PR)
position
detection
method
2050 absdir
Base point of
Z direction
2051 check
Check
2052 absg28 Width
compared by
G28
2053 absm02 Width
compared by
M02
6. Axis Specifications Parameters
6.3 Absolute Position Parameters
Details
Specify the absolute position zero point alignment
method.
0: Not absolute position detection
1: Stopper method (push onto mechanical stopper)
2: Marked point alignment method (align with
marked point)
3: Dog-type (align with dog and proximity switch)
9: Simple absolute position detection
(Not absolute position detection‚ but the position
when the power is turned off is registered.)
Automatic initial setting is valid only when the stopper
method is selected.
Set the direction of the grid point just before the marked
point (of the detector) when using marked point
alignment method.
Set the tolerable range for the movement amount
(deviation amount) when the power is turned off.
0: Not checked
1 to 99999.999mm: If the difference of the position
when the power is turned off and turned on
again is larger than this value‚ an alarm will be
output.
Specify the position comparison when executing G28
or G30.
The comparison results set the tolerable range.
0: No comparison
1 to 65535 (0.5 µm units):
If the results of the comparison of the value read
in from the detector and the position in the
control unit exceed this set value‚ an alarm will
be output‚ and the machine will stop.
The standard value is 100.
Specify the position comparison when executing M02
or M30.
The comparison results set the tolerable range.
0: Not compared
1 to 65535 (0.5 µm units):
If the results of the comparison of the value read
in from the detector and the position in the
control unit exceed this set value‚ an alarm will
be output‚ and the machine will stop.
The standard value is 100.
75
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0 to 9
0: Positive
direction
1: Negative
direction
0 to 99999.999
(mm)
0 to 65535
(0.5 µm)
0 to 65535 (µm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents