Buick LeSabre 1965 Service Manual page 573

Chassis 45000, 46000, 48000, 49000
Table of Contents

Advertisement

ELECTRICAL SYSTEMS
SPECIFICATIONS
1 0 - 3
10-4 IGNITION SYSTEM SPECIFICATIONS
a. Ignition Coil and Resistor
Make
Delco-Remy
Coil Number (Less Bracket)
1115087
Current Draw, Amperes @ 12.6 Volts
Engine Stopped
3.8
Engine Idling
2.3
Coil Resistance (Ohms) @ 80° F .
Primary
1.28 to 1.42
Secondary
7200 to 9500
Resistance Wire
Part of Wiring Harness
Resistance, Ohms @ 80° F
1.80 ± .05
b. Spark Plugs
Make and Model (for Normal Operation)
AC 44S
Make and Model (for High Speed Operation)
AC 42 COM
Thread and Shell Hex. Sizes
14MM, 13/16"
Gap at Points
035"
Tightening Torque (ft. lbs.)
30
c. Distributor
Make
Delco-Remy
Drive
From Camshaft
Rotation, Top View
Clockwise
Vacuum Control Number
1116210
Firing Order (300 Engine)
1-8-4-3-6-5-7-2
Firing Order (401 and 425 Engines)
1-2-7-8-4-5-6-3
Contact Point Opening
016"
Contact Point Dwell Angle
30° ± 1°
Dwell Variation
3° Max.
Breaker Arm Spring Tension, Ounces
19 to 23
Condenser Make and Capacity, Microfarads
Delco-Remy, .18 to .23
401 & 425 Engines
425 Engine
300 Engine
(Except Dual 4-Bbl.
(Dual 4-Bbl. with
with Auto. Trans.)
Auto. Trans.)
Distributor Number (less Cap)
1111083
1111055
1111058
Timing, Crankshaft Degrees before U.D.C.
(with Vacuum Hose Disconnected and Engine Idling) .
2 1/2°
2 1/2°
12°
Centrifugal Advance, Crankshaft Degrees and RPM
Start Advance, @ RPM
550 to 750
600 to 800
550 to 950
Medium Advance, Degrees @ RPM
12° to 16° @ 1400
13° to 17° @ 1400
1/2° to 4 1/2° @ 1000
Maximum Advance, Degrees @ RPM
30° to 34° @ 4600 28° to 32° @ 3900
18° to 22° @ 3800
Vacuum Advance, Crankshaft Degrees and Inches of Vacuum
Start Advance, @ In. of Vacuum
6 to 8
6 to 8
6 to 8
Maximum Advance, Degrees @ In. of Vacuum . . .
14° to 18° @ 16
14° to 18° @ 16
14° to 18° @ 16
10-5 LIGHTING SYSTEM SPECIFICATIONS
a. Lamps, Switches, Wiring
Headlamp Make and Type
Guide, Dual T-3 Sealed Beam
Headlamp Lens Diameter
5 3/4"
Tail, Stop, Parking, Signal Lamps, Make
Guide
Lighting Switch, Make
Delco-Remy
Wiring Circuit Type
Single Wire
Wiring Circuit Protection for Head and Front Parking Lights
Thermo Circuit Breaker
Thermo Circuit Breaker Location
In Lighting Switch
Thermo Circuit Breaker Calibration @ 75° F.
Stay Closed Indefinitely @ Amps
15
Open Within 60 Seconds @ Amps
26