10 Programming

Registers of basic flag numbers

Introduction
MR 2829
MR 2830
MR 2831
358
Multi-display mode lets you set the basic flag numbers for HMI keys via
registers.
Basic flag number for device 1
This module register contains the basic flag number for HMI # 1.
Module register properties
Values
-160 ... 2080
Value after reset
2000
Takes effect
On the next operation of a key
Basic flag number for device 2
This module register contains the basic flag number for HMI # 2.
Module register properties
Values
-160 ... 2080
Value after reset
2000
Takes effect
On the next operation of a key
Basic flag number for device 3
This module register contains the basic flag number for HMI # 3.
Module register properties
Values
-160 ... 2080
Value after reset
2000
Takes effect
On the next operation of a key