10.3.1 Acyclic data interchange

Introduction
Properties
Jetter AG
This chapter covers acyclic data interchange on the Jetter Ethernet system
bus.
Acyclic data interchange on the Jetter Ethernet system bus can be
characterized as follows:
Property
Architecture
Client
Server
Data
Access time
Configuration
Reach
Description
Client/server
Data interchange is initiated by the client.
The server gives a response to the request made
by the client.
Usage of unicast frames
Network access is made once.
JetSym:
Programming and debugging of application
programs
JetViewSoft:
Setting up a visualization application
Controllers:
Data interchange out of the application program
(NetCopy..., NetBit..., network register)
PC:
E.g. for database applications
Controllers, bus nodes and communication
modules:
E.g. variable or debugging server
PC:
Registers, inputs/outputs, STX variables,
application program
Controllers, bus nodes and communication
modules:
Registers, STX variables
It depends on the data transfer time and on the
server's processing time
Network registers:
Easy configuration in the application program
Else, both client and server are completely
configured by the operating system.
Using TCP/IP and UDP/IP frames allow for data
interchange exceeding the limits of one's own
subnet.
Programming