3
CM Detail tab
Soft key
Meaning
No direct
Three identical areas for the display of detailed
selection
information related to max. three freely selec-
possible
table components.
The components can be selected using the pull-
down menus above the diagrams. Once you
select a component, the display indicates its
name and an index (order of component defini-
tion).
Bar graph:
Seconds:
With Component Monitoring (option 155), the control
provides automatic monitoring of configured machine
components.
If configured correctly, the system will display warning
messages indicating an imminent overload condition
and error messages indicating that an overload
condition was detected. By responding in time to these
messages, you can take countermeasures to protect the
machine components from damage.
If configured incorrectly, inappropriate error messages
will impede or even prevent further work. In this case,
you can use the CfgComoUserData (no. 129400)
machine parameter to influence the configured overload
responses.
Further information:
Page 453
72
Individual view of the selected component
The red line shows the error limit defined by
the machine tool builder
The yellow line shows the warning limit
defined by the machine tool builder
The black line corresponds to the current load
condition
Individual display of the load duration
Red: duration in the overload zone
Yellow: duration in the warning zone
Green: duration in the zone defined as safe
"List of user parameter",
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 10/2018