12
Parameter settings
NC stop during tool check
NC stop during tool measurement
Change the tool table during tool check and tool measurement
Configuration of a round stylus
TT140_1
Coordinates of the stylus center
Set-up clearance above the stylus for pre-positioning
Safety zone around the stylus for prepositioning
460
True: When the breakage tolerance is exceeded, the NC program is stopped
False: The NC program is not stopped
True: When the breakage tolerance is exceeded, the NC program is stopped
False: The NC program is not stopped
AdaptOnMeasure: The table is changed after tool measurement
AdaptOnBoth: The table is changed after tool check and tool measurement
AdaptNever: The table is not changed after tool check and tool measurement
[0]: X coordinate of the stylus center with respect to the machine datum
[1]: Y coordinate of the stylus center with respect to the machine datum
[2]: Z coordinate of the stylus center with respect to the machine datum
0.001 to 99 999.9999 [mm]: Set-up clearance in tool-axis direction
0.001 to 99 999.9999 [mm]: Set-up clearance in the plane perpendicular to the
tool axis