HEIDENHAIN TNC 620 User Manual page 70

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

3
Coordinate transformations (TRANS tab)
Soft key
Meaning
Name of the active datum table
Active datum number (#), comment from the
active line of the active datum number (DOC)
from Cycle 7
Active datum shift (Cycle 7); the control displays
an active datum shift in up to 8 axes
Mirrored axes (Cycle 8)
Active rotation angle (Cycle 10)
Active scaling factor/factors (Cycle 11 / 26); the
control displays an active scaling factor in up to 6
axes
Scaling datum
In the optional machine parameter CfgDisplayCoordSys
(no. 127501) you can specify the coordinate system in
which the status display shows an active datum shift.
Further information:
Further information:
Programming or ISO Programming
Displaying Q parameters (QPARA tab)
Soft key
Meaning
Display the current values of the defined
Q parameters
Display the character strings of the defined string
parameters
Press the Q PARAMETER LIST soft key. The control
opens a pop-up window. For each parameter type (Q,
QL, QR, QS), define the parameter numbers you wish to
check. Separate single Q parameters with a comma, and
connect sequential Q parameters with a hyphen, e.g.
1,3,200-208. The input range per parameter type is 132
characters.
The display in the QPARA tab always contains eight
decimal places. The result of Q1 = COS 89.999 is
shown by the control as 0.00001745, for example.
Very large and very small values are displayed by
the control in exponential notation. The result of
Q1 = COS 89.999 * 0.001 is shown by the control as
+1.74532925e-08, whereby e-08 corresponds to the
factor of 10
70
Cycle Programming User's Manual
User's Manual for Conversational
.
-8
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 10/2018