Setup | Presetting with a 3-D touch probe (option number 17)
Presetting on any axis
HEIDENHAIN only gives warranty for the function of the
probing cycles if HEIDENHAIN touch probes are used.
Select the probing function: Press the
POSITION PROBING soft key
Move the touch probe to a position near the
touch point
Select the axis and probing direction, e.g. Probe
in direction Z-
Probe: Press the NC Start key
Preset: Enter the nominal coordinate
Load with the SET PRESET soft key
Further information:
from the touch probe cycles to a datum table",
Page 201
Further information:
from the touch probe cycles to the preset table",
Page 202
Terminate the probing function: Press the END
soft key
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 10/2018
"Writing measured values
"Writing measured values
5
217