5
Saving table rotation in the preset table
You can save the misalignment of the rotary table in any row of the
preset table. The control stores the angle in the offset column of
the rotary table, e.g. in the C_OFFS column for a C axis.
Press the TABLE ROT. IN PRESET TABLE soft key after the
probing procedure
If appropriate, the control opens the Overwrite active preset?
menu.
Press the OVERWRITE PRESET soft key
The control saves the offset in the preset table.
You may have to change the view in the preset table with the
BASE TRANSFORM./OFFSET soft key for this column to be
displayed.

Showing basic rotation and offset

If you select the PROBING ROT function, the control displays the
active angle of the basic rotation in the Angle of basic rotation
input field and the active offset in the Offset of rotary table input
field.
In addition, the basic rotation and the offset are shown in the
PROGRAM + STATUS screen layout on the STATUS POS. tab.
When the control moves the machine axis in accordance with the
basic rotation, a symbol for the basic rotation is shown in the status
display.
Rescinding basic rotation or offset
Select the probe function by pressing the PROBING ROT soft
key
Enter the Angle of basic rotation: 0
Alternative: Enter the Offset of rotary table: 0
Apply with the SET BASIC ROTATION soft key
Alternative: Apply with the SET TABLE ROTATION soft key
Terminate the probing function: Press the END soft key
212
Setup | Compensating workpiece misalignment with 3-D touch probe (option 17)
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 10/2018