HEIDENHAIN TNC 620 User Manual page 370

Setup, testing and running nc programs
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

10
Manual installation of a session certificate
A new certificate must be installed if no valid session certificate
is installed on the control. Clarify which certificate is needed
with your service employee. He will then provide you with a valid
certificate file if necessary.
Proceed as follows to install the certificate on the control:
Taskbar at the bottom edge of the screen
Further information:
Press the green HEIDENHAIN button to open the JH menu
Select the Settings menu item
Select the Network menu item
The control displays the Network settings dialog.
Select the Internet tab. The settings in the Remote
maintenance field are configured by the machine tool builder.
Press the Add button
Select the file in the selection menu
Press the Open key
The certificate is opened.
Press the OK soft key
It may be necessary to restart the control to load the settings
Launching the service session
Proceed as follows to start the service session:
Open the task bar at the bottom edge of the screen
Press the green HEIDENHAIN button to open the JH menu
Select the Diagnostic menu item
Select the RemoteService menu item
Enter the Session key of the machine tool builder
370
"Window manager", Page 364
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 10/2018
HEROS functions | Window manager