Note:
Daylight Saving Time adjustment. Attempting to configure a Local clock using
Data Format 2 with either a Time Zone Offset or automatic DST rule will result in
an error message.
E x a m p l e m e s s a g e :
CR LF IQYY ^ DDD ^ HH:MM:SS.SSS ^ LD
Where:
CR
Carriage Return
LF
Line Feed
I
Time Sync Status (space, ?, *)
Q
Quality Indicator (space, A, B, C, D)
YY
Year without century (99, 00, 01, etc.)
^
Space separator
DDD
Day of Year (001-366)
HH
Hours (00-23 UTC time)
:
Colon separator
MM
Minutes (00-59)
:
Colon separator
SS
(00-60)
.
Decimal separator
SSS
Milliseconds (000-999)
L
Leap Second indicator (space, L)
D
Daylight Saving Time Indicator (S,I,D,O)
The leading edge of the first character (
The time synchronization status character (
? When the receiver is unable to track any satellites and the time synchronization lamp is red.
VersaSync User Manual
Format 2 cannot be configured for a Time Zone Offset or with automatic
) marks the on-time point of the data stream.
CR
) is defined as described below:
I