3.3 Managing References
1.
The optional BroadShield software license needs to be enabled by applying the OPT-
BSH BroadShield license key. For more information, contact your local Spectracom Sales
Office. To determine if BroadShield has been activated on your VersaSync unit, nav-
igate to TOOLS: SYSTEM > Upgrade/Backup . The center panel System Configuration will
list the Options installed in your unit.
2.
BroadShield only works with a u-blox M8T receiver , not with Trimble receivers. To determ-
ine which receiver is installed in your unit, navigate to TOOLS: SYSTEM >
Upgrade/Backup . The center panel System Configuration will list the GNSS Receiver
installed in your unit.
3.
System Software 5.7.1 or higher must be installed in your unit. To determine which soft-
ware is installed in your unit, follow the instructions above and locate the System line
item in the System Configuration panel.
Activating the BroadShield License
If you have purchased the BroadShield license key and now want to activate it, please follow
the instructions under "Applying a License File" on page 222.
To confirm that BroadShield has been activated on your VersaSync unit, navigate to TOOLS:
SYSTEM > Upgrade/Backup . The center panel System Configuration will list the Options installed
in your unit.
Enabling/Disabling the BroadShield Service
The Broadshield service can be run in two operating modes:
BroadShield only : In the event jamming or spoofing is detected, VersaSync will emit a
Major Alarm, however it will continue to consider the GNSS reference as valid, i.e. it
will NOT go out of sync.
Auto Sync Control : In the event jamming or spoofing is detected, VersaSync will emit a
Major Alarm AND it will go into Holdover mode.
To configure these settings:
1.
Navigate to MONITORING > BroadShield .
2.
In the BroadShield Service panel on the left, configure the desired setting:
140
CHAPTER
•
3
VersaSync User Manual Rev. 6.0
Need help?
Do you have a question about the VersaSync and is the answer not in the manual?
Questions and answers