Test Port Input - HP 8719ET Reference Manual

Network analyzers
Hide thumbs Also See for HP 8719ET:
Table of Contents

Advertisement

Test Port Input

Table 2-13 Test Port Input
HP 8719ET/20ET/22ET Test Port Input
Description
Frequency Range
HP 8719ET
HP 8720ET
HP 8722ET
Frequency Response (B, R)
Channel R
0.05 to 20.05 GHz
20.05 to 32 GHz
32 to 40 GHz
Channel B
0.05 to 20.05GHz
20 to 32 GHz
32 to 40 GHz
Impedance
Standard
Return Loss
Standard
Maximum Input Level
Standard
Damage Level
Standard
Compression
a. Maximum level at which no test port overload messages are seen.
Specification
0.05 to 13.51 GHz
0.05 to 20.05 GHz
0.05 to 40.05 GHz
a
+5 dBm, Transmission Port
+10 dBm, Reflection Port
HP 8719/20/22ET Specifications and Characteristics
Supplemental Information
± 1.5 dB, char.
± 2.5 dB, char.
+2.5 dB to −6 dB, char.
± 2.5 dB, char.
± 3.0 dB, char.
+3.0 dB to −6 dB, char.
50 Ω, nominal.
See uncorrected load match chart.
+27 dBm or > 0 Vdc, typ.
See dynamic accuracy chart.
Instrument Specifications