Table 1-12 2.4-mm Device Connector Type
Network Analyzer: HP 8722ES, Standard
Calibration Kit: HP 85056A (2.4-mm, 50 Ω)
Cables: HP 85133F
Calibration: Full 2-Port
IF BW = 10 Hz, Avg off, Temp = 23 ± 3°C with < 1°C deviation from cal temp, Isol cal with avg = 8
Description
Directivity (dB)
Source Match (dB)
Load Match (dB)
Refl. Tracking
±(0.005 + .03/°C)
Magnitude (dB)
±(0.033 + 0.1/°C)
Phase (deg)
Trans. Tracking
±(0.020 + .03/°C)
Magnitude (dB)
±(0.132 + 0.1/°C)
Phase (deg)
Transmission Uncertainty (Specification)
Reflection Uncertainty (Specification)
0.05 to 2 GHz
2 to 8 GHz
42
41
42
±(0.010 + .03/°C)
±(0.066 + 0.3/°C)
±(0.038 + .03/°C)
±(0.251 + 0.3/°C)
HP 8719/20/22ES Specifications and Characteristics
Corrected System Performance (HP 8722ES)
Specification
8 to 20 GHz
42
42
38
38
42
42
±(0.010 + .04/°C)
±(0.066 + 0.5/°C)
±(0.048 + .04/°C)
±(0.317 + 0.5/°C)
20 to 40 GHz
38
33
38
±(0.021 + .06/°C)
±(0.139 + 1.0/°C)
±(0.110 + .06/°C)
±(0.736 + 1.0/°C)