Hardkey/Softkey Reference
Analyzer Functions
RESTORE DISPLAY
RESUME CAL SEQUENCE
RETRACE PWR on STD
REV ISOL'N
REV ISOL'N ISOL'N STD
(Label Class)
REV MATCH
(Specify Class) specifies which standards are in the reverse match class in
REV MATCH
REV MATCH THRU
(Label Class)
REV TRANS
(Specify Class)
REV TRANS
REV TRANS THRU
REVERSE: OPENS
RF > LO
RF < LO
5-48
isolation is an impedance-matched load (usually 50 or
75 Ωs). Response and directivity calibration procedures
for reflection and transmission measurements are
provided in the following pages.
turns off the tabular listing and returns the measurement
display to the screen.
eliminates the need to restart a calibration sequence that
was interrupted to access some other menu. This softkey
goes back to the point where the calibration sequence was
interrupted.
when on, causes the analyzer to retrace the sweep only
over the current frequency range, and does not turn off the
power during retrace, unless crossing a 20.05 GHz source
band. When in STD mode, the analyzer may turn off the
source power, or sweep to a lower frequency if it provides a
faster retrace.
measures the reverse isolation of the calibration standard
during an enhanced response cal.
measures the reverse isolation of the calibration standard
during a full 2-port cal.
lets you enter a label for the reverse match class. The label
appears during a calibration that uses this class.
the calibration kit.
is used to enter the standard numbers for the reverse
match (thru) calibration. (For default kits, this is the
thru.)
lets you enter a label for the reverse transmission class.
The label appears during a calibration that uses this class.
specifies which standards are in the reverse transmission
class in the calibration kit.
is used to enter the standard numbers for the reverse
transmission (thru) calibration. (For default kits, this is
the thru.)
provides access to the menu for selecting an open
calibration type when the cal kit defines more than one
open standard.
adjusts the source frequency higher than the LO by the
amount of the LO (within the limits of the analyzer).
adjusts the source frequency lower than the LO by the
amount of the LO (within the limits of the analyzer).