RAW OFFSET On Off
Re/Im MKR
READ FILE TITLES
READ SEQ FILE TITLS
REAL
RECALL CAL PORT 1
RECALL CAL PORT 2
selects whether sampler and attenuator offsets are ON or
OFF. By selecting raw offsets OFF, a full two port error
correction can be performed without including the effects
of the offsets. It also saves substantial time at recalls and
during frequency changes. Raw offsets follow the channel
coupling. This softkey is used with "Take4" mode. Refer to
the examples in the programmer's guide.
when in the smith marker menu,
the values of the active marker on a Smith chart as a real
and imaginary pair. The complex data is separated into its
real part and imaginary part. The first marker value given
is the real part M cos θ, and the second value is the
imaginary part M sin θ, where M = magnitude.
When in the polar marker menu,
the values of the active marker as a real and imaginary
pair. The complex data is separated into its real part and
imaginary part. The first marker value given is the real
part M cos θ, and the second value is the imaginary part M
sin θ, where M = magnitude.
searches the directory of the disk for file names recognized
as belonging to an instrument state, and displays them in
the softkey labels. No more than five titles are displayed at
one time. If there are more than five, repeatedly pressing
this key causes the next five to be displayed. If there are
fewer than five, the remaining softkey labels are blanked.
is a disk file directory command. Pressing this softkey will
read the first six sequence titles and display them in the
softkey labels. These sequences can then be loaded into
internal memory.
If
READ SEQ FILE TITLS
sequence titles on the disk will be displayed. To read the
contents of the disk starting again with the first sequence:
remove the disk, reinsert it into the drive, and press
READ SEQ FILE TITLS
displays only the real (resistive) portion of the measured
data on a Cartesian format. This is similar to the linear
magnitude format, but can show both positive and
negative values. It is primarily used for analyzing
responses in the time domain, and also to display an
auxiliary input voltage signal for service purposes.
Press this key after selecting the file associated with port 1
error correction for adapter removal calibration.
Press this key after selecting the file associated with port 2
error correction for adapter removal calibration.
Hardkey/Softkey Reference
Analyzer Functions
Re/Im MKR
Re/Im MKR
is pressed again, the next six
.
displays
displays
5-45