Selection Of The Power Supply Unit; Pin Allocation Of Power Supply - Festo CPX-FB6 Manual

Cpx fieldbus node
Hide thumbs Also See for CPX-FB6:
Table of Contents

Advertisement

1. Installation
1.5

Selection of the power supply unit

1.6

Pin allocation of power supply

Festo P.BE-CPX-FB6-EN en 1207c
Warning
Only use PELV circuits in accordance with IEC/EN
60204-1 (protective extra-low voltage, PELV) for the elec-
trical power supply.
Also take into account the general requirements for PELV
circuits in accordance with
IEC/EN 60204-1.
Use only voltage sources that guarantee reliable electric-
al isolation of the operating voltage according to IEC/
DIN EN 60204-1.
Through the use of PELV circuits, protection against electric
shock (protection against direct and indirect contact) is en-
sured in accordance with IEC/EN 60204-1.
The current consumption of a CPX terminal depends on the
number and type of integrated modules and components.
Observe the information on power supply as well as on the
earthing measures to be carried out in the CPX system de-
scription.
1-23