● DD: MIDDLE Total Power Consumption Every Five-minute Period (0.001-kWh
increments) KM50-E Only
The MIDDLE total power consumption for every five-minute period can be read.
The MIDDLE total power consumption for every five-minute period can be read for only two days,
the present day and the previous day.
Specify the address for the time period to read in the service request PDU.
Example for Address 0001: The MIDDLE total power consumption from 00:00 to 00:10 will be
read.
(The MIDDLE total power consumption for the specified time will be read.)
The MIDDLE total power consumption for every five-minute period for the present day cannot be
read for times that are in the future compared to the present time in the KM50 internal clock. If the
MIDDLE total power consumption is read for future times, the service response PDU will be
returned with a measurement value of 0.
The address are listed in the following table.
(Addresses are incremented by one for each five minutes, so some addresses have been omitted.)
Variable
Address
type
MIDDLE Total Power
DD
0000
Consumption for 00:00 to
00:05 Today (kWh)
MIDDLE Total Power
DD
0001
Consumption for 00:05 to
00:10 Today (kWh)
MIDDLE Total Power
DD
0002
Consumption for 00:10 to
00:15 Today (kWh)
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
MIDDLE Total Power
DD
011E
Consumption for 23:50 to
23:55 Today (kWh)
MIDDLE Total Power
DD
011F
Consumption for 23:55 to
24:00 Today (kWh)
MIDDLE Total Power
DD
0120
Consumption for 00:00 to
00:05 Yesterday (kWh)
MIDDLE Total Power
DD
0121
Consumption for 00:05 to
00:10 Yesterday (kWh)
MIDDLE Total Power
DD
0122
Consumption for 00:10 to
00:15 Yesterday (kWh)
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
MIDDLE Total Power
DD
023E
Consumption for 23:50 to
23:55 Yesterday (kWh)
MIDDLE Total Power
DD
023F
Consumption for 23:50 to
24:00 Yesterday (kWh)
3-30
Parameter name
0000 0000 to 0098 967F hex (0.000 to 9,999.999)
*Three digits to the right of the decimal point (fixed).
Same as above.
Same as above.
⋅ ⋅ ⋅
(Omitted)
⋅ ⋅ ⋅
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
⋅ ⋅ ⋅
(Omitted)
⋅ ⋅ ⋅
Same as above.
Same as above.
Set value (monitor value)