D1: Total Power Consumption Every Five Minutes (0.1-Kwh Increments) - Omron KM50 Communications Manual

Smart power monitor
Table of Contents

Advertisement

Section 3 CompoWay/F Communications Data
● D1: Total Power Consumption Every Five Minutes (0.1-kWh increments)
The total power consumption every five minutes can be read.
The total power consumption very five minutes can be read for only two days, the present day and
the previous day.
Specify the address for the time period to read in the service request PDU.
Example for Address 0001: The total power consumption at 00:10 will be read.
(The total power consumption for the specified time will be read.)
The total power consumption every five minutes for the present day cannot be read for times that
are in the future compared to the present time in the KM50 internal clock. If the total power
consumption is read for future times, the service response PDU will be returned with a
measurement value of 0.
The addresses are listed in the following table.
(Addresses are incremented by one for each five minutes, so some addresses have been omitted.)
Variable
Address
type
Total Power Consumption for
D1
0000
00:05 Today (kWh)
Total Power Consumption for
D1
0001
00:10 Today (kWh)
Total Power Consumption for
D1
0002
00:15 Today (kWh)
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
Total Power Consumption for
D1
011E
23:55 Today (kWh)
Total Power Consumption for
D1
011F
24:00 Today (kWh)
Total Power Consumption for
D1
0120
00:05 Yesterday (kWh)
Total Power Consumption for
D1
0121
00:10 Yesterday (kWh)
Total Power Consumption for
D1
0122
00:15 Yesterday (kWh)
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
Total Power Consumption for
D1
023E
23:55 Yesterday (kWh)
Total Power Consumption for
D1
023F
24:00 Yesterday (kWh)
3-14
Parameter name
0000 0000 to 05F5 E0FF hex (0.0 to 9,999,999.9)
*One digit to the right of the decimal point (fixed).
Same as above.
Same as above.
⋅ ⋅ ⋅
(Omitted)
⋅ ⋅ ⋅
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
⋅ ⋅ ⋅
(Omitted)
⋅ ⋅ ⋅
Same as above.
Same as above.
Set value (monitor value)