Address
Parameter name
4710
Active Power
Seven Days
Ago
4711
4800
Voltage 1 Eight
Days Ago
4801
4802
Voltage 2 Eight
Days Ago
4803
4804
Voltage 3 Eight
Days Ago
4805
4806
Current 1 Eight
Days Ago
4807
4808
Current 2 Eight
Days Ago
4809
480A
Current 3 Eight
Days Ago
480B
480C
Power Factor
Eight Days
480D
Ago
480E
Active Power
Eight Days
Ago
480F
4810
Active Power
Eight Days
Ago
4811
5-24
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
0000 0000 to 3B9A C9FF hex (0.00 to 9,999,999.99)
Value (kW)
*Two digits to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
0000 0000 to 000F 423F hex (0.0 to 99,999.9)
Value (V)
*One digit to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
0000 0000 to 000F 423F hex (0.0 to 99,999.9)
Value (V)
*One digit to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
0000 0000 to 000F 423F hex (0.0 to 99,999.9)
Value (V)
*One digit to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
0000 0000 to 0098 967F hex (0.000 to 99,999.999)
Value (A)
*Three digits to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
0000 0000 to 0098 967F hex (0.000 to 99,999.999)
Value (A)
*Three digits to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
0000 0000 to 0098 967F hex (0.000 to 99,999.999)
Value (A)
*Three digits to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
FFFF FF9C to 0000 0064 hex (−1.00 to 1.00)
Value
*Two digits to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
C465 3601 to 3B9A C9FF hex (−99,999,999.9 to 99,999,999.9)
Value (W)
*One digit to the right of the decimal point (fixed).
Measurement
0000 HHMM hex
Time
HH (hour): 0 to 17 hex (0 to 23), MM (minutes): 0 to 3B hex (0 to 59)
Measurement
C465 3601 to 3B9A C9FF hex (−9,999,999.99 to 9,999,999.99)
Value (kW)
*Two digits to the right of the decimal point (fixed).