Response Codes - Omron KM50 Communications Manual

Smart power monitor
Table of Contents

Advertisement

2.4

Response Codes

Normal Completion
Response
Name
code
0000
Normal completion
Error Completion
Response
Name
code
0401
Unsupported command
1001
Command too long
1002
Command too short
1101
Area type error
Start address out-of-range
1103
error
Number of elements/data
1003
mismatch
110B
Response too long
1100
Parameter error
2203
Operation error
Description
No errors were detected.
Description
The service function for the relevant command is not
supported.
The command is too long.
The command is too short.
The area type (variable or parameter) is wrong.
The read/write start address is out of range.
The amount of data does not match the number of
elements.
The response exceeds the communications buffer
size.
Bit position is not 00.
The write data is out of range.
The command code or related information for an
operation command is wrong.
The time data is not correct.
The operation command cannot be processed.
2.4

Response Codes

Error
detection
priority
None
Error
detection
priority
1
2
3
4
5
6
7
8
9
2-21