■ Echoback Test

• Command Frame
Slave
Function
address
code
08 hex
1
1
• Response Frame
Slave
Function
address
code
08 hex
1
1
• If the command is executed normally, the response returns the data that was sent in the
command.
(1) Test Data
Enter any 2-byte hexadecimal data.
(2) Response Codes
Function code
88 hex
08 hex
● Example Command and Response
The following example is for Echoback Test.
(In this case, the test data is 1234 hex and the slave address is 01 hex.)
Command:
Response:
Write start
address
Test data
00 hex
00 hex
2
Write start
Test data
address
00 hex
00 hex
2
Error code
Name
03 hex
Variable data error
Normal completion
01
08
00 00
01
08
00 00
4. 4 Detailed Descriptions of Services
CRC-16
2 bytes
2
CRC-16
2 bytes
2
Description
The data following the function code
was not the fixed data (00 hex, 00 hex).
No errors were detected.
12 34
ED 7C (CRC-16)
12 34
ED 7C (CRC-16)
4-13