Section 3 CompoWay/F Communications Data
Parameter type Address
C000
0049
C000
004A
C000
004B
C000
004C
C000
004D
C000
004E
C000
004F
C000
0050
C000
0051
C000
0052
*5*7
C000
0053
*5
C000
0054
*5
C000
0055
*5
C000
0056
*5
C000
0057
*5
C000
0058
C000
0059
C000
005A
C000
005B
C000
005C
C000
005D
C000
005E
C000
005F
C000
0060
C000
0061
C000
0062
C000
0063
3-48
Default
Parameter name
setting
Reactive Power
0.0 s
Alarm ON Delay
Reactive Power
*8
Alarm Lower Limit
0.0%
Threshold
Output Terminal 1
Pulse
Function Setting
output
Output Terminal 2
Alarm
*5
Function Setting
Output
Active Power Alarm
Setting (Output
OFF
Terminal 1)
Regenerative Power
Alarm Setting
OFF
(Output Terminal 1)
Current Alarm
Setting (Output
OFF
Terminal 1)
Voltage Alarm
Setting (Output
OFF
Terminal 1)
Power Factor Alarm
Setting (Output
OFF
Terminal 1)
Reactive Power
Alarm Setting
OFF
(Output Terminal 1)
Reactive Power
Alarm Setting
OFF
(Output Terminal 2)
Regenerative Power
Alarm Setting
OFF
(Output Terminal 2)
Current Alarm
Setting (Output
OFF
Terminal 2)
Voltage Alarm
Setting (Output
OFF
Terminal 2)
Power Factor Alarm
Setting (Output
OFF
Terminal 2)
Reactive Power
Alarm Setting
OFF
(Output Terminal 2)
Automatic Rotation
OFF
Function
Transition Time
3 s
Active Power Display
Display.
Selection
Total Power
Consumption Display
Display.
Selection
Current 1 Display
Display.
Selection
Current 2 Display
Display.
Selection
Current 3 Display
Display.
Selection
Voltage 1 Display
Display.
Selection
Voltage 2 Display
Display.
Selection
Voltage 3 Display
Display.
Selection
Power Factor Display
Display.
Selection
Set value (monitor value)
0000 0000 to 0000 03E7 hex (0.0 to 99.9 s)
*One digit to the right of the decimal point (fixed).
0000 0000 to 0000 05DC hex (0.0% to 150.0%)
*One digit to the right of the decimal point (fixed).
0000 0000 hex: OFF
0000 0001 hex: Pulse output
0000 0002 hex: Alarm output
0000 0000 hex: OFF
0000 0001 hex: Pulse output
0000 0002 hex: Alarm output
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex: OFF
0000 0001 hex: ON
0000 0000 hex:
OFF
0000 0001 hex:
ON
0000 0001 to 0000 0063 hex (1 to 99 s)
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.
0000 0000 hex: Do not display.
0000 0001 hex: Display.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents