Variable
Address
Parameter name
type
Pulse Input Count 2 for the
*6
0038
C0
Day (pulses)
0039
C0
Temperature (°C or F)
Converted Monetary Cost
C0
003A
(upper digits)
Converted Monetary Cost
003B
C0
(lower digits)
HIGH Total Power
Consumption Converted to
*3
C0
003C
Monetary Cost (upper
*8
digits)
HIGH Total Power
*3
003D
Consumption Converted to
C0
Monetary Cost (lower digits)
MIDDLE Total Power
Consumption Converted to
*3
C0
003E
Monetary Cost (upper
*8
digits)
MIDDLE Total Power
*3
003F
Consumption Converted to
C0
Monetary Cost (lower digits)
LOW Total Power
Consumption Converted to
*3
C0
0040
Monetary Cost (upper
*8
digits)
LOW Total Power
*3
0041
Consumption Converted to
C0
Monetary Cost (lower digits)
Pulse Conversion Value 1
0042
C0
(upper digits)
Pulse Conversion Value 1
C0
0043
(lower digits)
Pulse Conversion Value 2
0044
C0
(upper digits)
Pulse Conversion Value 2
0045
C0
(lower digits)
*1 Currents 1, 2, and 3 that are read with the previous addresses are in the following order for
the wiring methods. These are in a different order from currents 1, 2, and 3 that are read with
the new address.
Wiring method
Single-phase,
2-wire
Single-phase,
3-wire
Three-phase,
3-wire
Three-phase,
4-wire
---: These values will read as 0.
0000 0000 to 0001 869F hex (0 to 99,999)
FFFF FF6A to 0000 0578 hex (−15.0 to 140.0)
*One digit to the right of the decimal point (fixed).
*5
Note: In the range of −15.0 to 60.0 for Celsius, and 5.0 to 140.0
for Fahrenheit.
0000 0000 to 3B9A C9FF hex (0 to 999,999,999)
*Indicates values above 1M. Starts from 0 if the value exceeds
*8
the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999.999)
*Three digits to the right of the decimal point (fixed). Starts from
*8
0 if the value exceeds the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999,999)
*Indicates values above 1M. Starts from 0 if the value exceeds
the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999.999)
*Three digits to the right of the decimal point (fixed). Starts from
*8
0 if the value exceeds the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999,999)
*Indicates values above 1M. Starts from 0 if the value exceeds
the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999.999)
*Three digits to the right of the decimal point (fixed). Starts from
*8
0 if the value exceeds the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999,999)
*Indicates values above 1M. Starts from 0 if the value exceeds
the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999.999)
*Three digits to the right of the decimal point (fixed). Starts from
*8
0 if the value exceeds the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999,999)
*Indicates values above 1M. Starts from 0 if the value exceeds
*8
the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999.999)
*Three digits to the right of the decimal point (fixed). Starts from
*8
0 if the value exceeds the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999,999)
*Indicates values above 1M. Starts from 0 if the value exceeds
*8
the range.
0000 0000 to 3B9A C9FF hex (0 to 999,999.999)
*Three digits to the right of the decimal point (fixed). Starts from
*8
0 if the value exceeds the range.
Previous addresses
Current 1
Current 2
Current 3
---
---
IR
IR
IT
IN
IR
IT
IS
IR
IT
IS
3. 1 Variable Area
Set value (monitor value)
New addresses
Current 1
Current 2
Current 3
---
---
IR
IR
IN
IT
IR
IS
IT
IR
IS
IT