● D3: Total @@ Power Consumption Every Five Minutes (0.001-kWh increments)
The total power consumption can be read for every five minutes for any of four total power
consumptions. The total @@ power consumption every five minutes can be read for only two days,
the present day and the previous day.
(@@: Regenerative, leading reactive, lagging reactive, or reactive)
Specify the address for the time to read in the service request PDU.
Example for Address 0001: The total @@ power consumption for 00:10 will be read.
(The total @@ power consumption for the specified time will be read.)
The total @@ power consumption every five minutes for the present day cannot be read for times
that are in the future compared to the present time in the KM50 internal clock. If a value is read for
a future time, the service response PDU will be returned with a measurement value of 0.
If the read value exceeds 9,999 kWh, the precision of the lowest digit will be lost, so FFFF FFFF
will be returned as the measurement value in the service response PDU. If that occurs, read the
measurement value for 0.1-kWh increments.
The address are listed in the following table.
Addresses are incremented by one for each five minutes. Some addresses have been omitted in
the following table.
Variable
Address
type
Total @@ Power
D3
0800
Consumption for 00:05
Today (kWh)
Total @@ Power
D3
0801
Consumption for 00:10
Today (kWh)
Total @@ Power
D3
0802
Consumption for 00:15
Today (kWh)
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
Total @@ Power
D3
091E
Consumption for 23:55
Today (kWh)
Total @@ Power
D3
091F
Consumption for 24:00
Today (kWh)
Total @@ Power
D3
0920
Consumption for 00:05
Yesterday (kWh)
Total @@ Power
D3
0921
Consumption for 00:10
Yesterday (kWh)
Total @@ Power
D3
0922
Consumption for 00:15
Yesterday (kWh)
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
⋅ ⋅ ⋅
Total @@ Power
D3
0A3E
Consumption for 23:55
Yesterday (kWh)
Total @@ Power
D3
0A3F
Consumption for 24:00
Yesterday (kWh)
Parameter
0000 0000 to 0098 967F hex (0.000 to 9,999.999)
*Three digits to the right of the decimal point (fixed).
Same as above.
Same as above.
⋅ ⋅ ⋅
(Omitted)
⋅ ⋅ ⋅
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
⋅ ⋅ ⋅
(Omitted)
⋅ ⋅ ⋅
Same as above.
Same as above.
3. 1 Variable Area
Set value (monitor value)