● Addresses 2200 to 2208 hex: Total Power Consumption for Every Day (0.1-kWh
Increments)
The total power consumption for every day can be read.
The total power consumption for every day can be read for the present day and the last eight days.
Specify the address for the day to read in the service request PDU.
Address
Parameter name
Present Total Power
2200
Consumption for Today (kWh)
Total Power Consumption for
2201
00:00 to 24:00 One Day Ago
(kWh)
Total Power Consumption for
2202
00:00 to 24:00 Two Days Ago
(kWh)
Total Power Consumption for
2203
00:00 to 24:00 Three Days
Ago (kWh)
Total Power Consumption for
2204
00:00 to 24:00 Four Days Ago
(kWh)
Total Power Consumption for
00:00 to 24:00 Five Days Ago
2205
(kWh)
Total Power Consumption for
2206
00:00 to 24:00 Six Days Ago
(kWh)
Total Power Consumption for
2207
00:00 to 24:00 Seven Days
Ago (kWh)
Total Power Consumption for
2208
00:00 to 24:00 Eight Days Ago
(kWh)
● Addresses 2300 to 2308 hex: Total Power Consumption for Every Day
(0.001-kWh Increments)
The total power consumption for every day can be read.
The total power consumption for every day can be read for the present day and the last eight days.
Specify the address for the day to read in the service request PDU.
If the read value exceeds 9,999 kWh, the precision of the lowest digit will be decreased, so FFFF
FFFF will be returned as the measurement value in the service response PDU. If that occurs, read
the measurement value for 0.1-kWh increments.
Address
Parameter name
Present Total Power Consumption for
2300
Today (kWh)
Total Power Consumption for 00:00 to
2301
24:00 One Day Ago (kWh)
Total Power Consumption for 00:00 to
2302
24:00 Two Days Ago (kWh)
Total Power Consumption for 00:00 to
2303
24:00 Three Days Ago (kWh)
Total Power Consumption for 00:00 to
2304
24:00 Four Days Ago (kWh)
Total Power Consumption for 00:00 to
2305
24:00 Five Days Ago (kWh)
Total Power Consumption for 00:00 to
2306
24:00 Six Days Ago (kWh)
Total Power Consumption for 00:00 to
2307
24:00 Seven Days Ago (kWh)
Total Power Consumption for 00:00 to
2308
24:00 Eight Days Ago (kWh)
Set value (monitor value)
0000 0000 to 05F5 E0FF hex (0.0 to 9,999,999.9)
*One digit to the right of the decimal point (fixed).
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Set value (monitor value)
0000 0000 to 0098 967F hex (0.000 to 9,999.999)
*Three digits to the right of the decimal point (fixed).
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.