VACON · 14
Language selection (P6.1)
1
Daylight saving* (P5.5.5)
2
3
Time* (P5.5.2)
4
Year* (P5.5.4)
5
Date* (P5.5.3)
* If a battery is installed, you see these steps.
Run Startup wizard?
6
To set the parameter values manually, make the selection No and push the OK button.
Make a selection of an application (P1.2 Application,
ID212)
7
Set a value for P3.1.2.2 Motor Type (so that it agrees
with the nameplate)
8
Set a value for P3.1.1.1 Motor Nominal Voltage (so
9
that it agrees with the nameplate)
Set a value for P3.1.1.2 Motor Nominal Frequency
10
(so that it agrees with the nameplate)
Set a value for P3.1.1.3 Motor Nominal Speed (so
11
that it agrees with the nameplate)
12
Set a value for P3.1.1.4 Motor Nominal Current
13
Set a value for P3.1.1.5 Motor Cos Phi
If you set Motor Type to Induction Motor, you see the next step. If your selection is PM Motor,
the value of parameter P3.1.1.5 Motor Cos Phi is set to 1.00 and the wizard goes directly to
step 14.
1
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
QUICK STARTUP GUIDE
The selection is different in all the language
packages
Russia
US
EU
OFF
hh:mm:ss
yyyy
dd.mm.
Yes
No
Standard
Local/Remote
Multi-step speed
PID control
Multi-purpose
Motor potentiometer
PM motor
Induction motor
Reluctance motor
Range: Varies
Range: 8.00...320.00 Hz
Range: 24...19200
Range: Varies
Range: 0.30-1.00