Vacon 100 Industrial Applications Manual page 283

Ac drives
Hide thumbs Also See for 100 Industrial:
Table of Contents

Advertisement

PARAMETER DESCRIPTIONS
The maximum value is taken from the set signals and used for alarm and fault triggering.
NOTE!
Only the 6 first temperature inputs are supported (the boards from slot A to slot E).
P3.9.6.2 ALARM LIMIT 1 (ID 741)
Use this parameter to set the temperature alarm limit.
Only the inputs that are set with parameter P3.9.6.1 are compared.
P3.9.6.3 FAULT LIMIT 1 (ID 742)
Use this parameter to set the temperature fault limit.
Only the inputs that are set with parameter P3.9.6.1 are compared.
P3.9.6.4 FAULT LIMIT RESPONSE 1 (ID 740)
Use this parameter to select the response of the drive to 'Temperature' fault.
P3.9.6.5 TEMPERATURE SIGNAL 2 (ID 763)
Use this parameter to select the temperature input signals that are supervised.
The maximum value is taken from the set signals and used for alarm and fault triggering.
NOTE!
Only the 6 first temperature inputs are supported (the boards from slot A to slot E).
P3.9.6.6 ALARM LIMIT 2 (ID 764)
Use this parameter to set the temperature alarm limit.
Only the inputs that are set with parameter P3.9.6.5 are compared.
P3.9.6.7 FAULT LIMIT 2 (ID 765)
Use this parameter to set the temperature fault limit.
Only the inputs that are set with parameter P3.9.6.5 are compared.
P3.9.6.8 FAULT LIMIT RESPONSE 2 (ID 766)
Use this parameter to select the response of the drive to 'Temperature' fault.
NOTE!
Temperature input settings are only available if a B8 or BH option board is
installed.
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
VACON · 283