Vacon 100 Industrial Applications Manual page 112

Ac drives
Hide thumbs Also See for 100 Industrial:
Table of Contents

Advertisement

VACON · 112
Table 45: Joystick control parameters
Index
Parameter
Joystick Signal
P3.3.5.1
Selection
P3.3.5.2
Joystick Dead Zone
P3.3.5.3
Joystick Sleep Zone
P3.3.5.4
Joystick Sleep Delay
Table 46: Jogging parameters
Index
Parameter
P3.3.6.1
Enable DI Jogging
Jogging Reference 1
P3.3.6.2
Activation
Jogging Reference 2
P3.3.6.3
Activation
P3.3.6.4
Jogging Reference 1
P3.3.6.5
Jogging Reference 2
P3.3.6.6
Jogging Ramp
* = The selection of the application with parameter P1.2 Application gives the default value.
See the default values in Chapter 12 Appendix 1.
5
Min
Max
Unit
0
6
0.0
20.0
%
0.0
20.0
%
0.00
300.00
Min
Max
Unit
Varies
Varies
Varies
Varies
Varies
Varies
-MaxRef
MaxRef
Hz
-MaxRef
MaxRef
Hz
0.1
300.0
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
Default
ID
0 = Not Used
1 = AI1 (0-100%)
2 = AI2 (0-100%)
0
451
3 = AI3 (0-100%)
4 = AI4 (0-100%)
5 = AI5 (0-100%)
6 = AI6 (0-100%)
2.0
384
0.0
385
0 = Not used
s
0.00
386
0 = Not used
Default
ID
DigIN
532
Slot0.1
DigIN
530
Slot0.1
DigIN
531
Slot0.1
0.00
1239
0.00
1240
s
10.0
1257