Vacon 100 Industrial Applications Manual page 108

Ac drives
Hide thumbs Also See for 100 Industrial:
Table of Contents

Advertisement

VACON · 108
Table 39: Frequency reference parameters
Index
Parameter
Keypad Control Ref-
P3.3.1.7
erence Selection
P3.3.1.8
Keypad Reference
P3.3.1.9
Keypad Direction
Fieldbus Control
P3.3.1.10
Reference Selection
* = The selection of the application with parameter P1.2 Application gives the default value.
See the default values in Chapter 12 Appendix 1.
5
Min
Max
Unit
0
19
P3.3.1.1
P3.3.1.2.
Hz
0
1
0
19
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
PARAMETERS MENU
Default
ID
Description
0 = Preset Frequency 0
1 = Keypad
2 = Fieldbus
3 = AI1
4 = AI2
5 = AI1+AI2
6 = PID reference
7 = Motor potentiome-
ter
8 = Joystick
2 *
121
9 = Jogging reference
10 = Block Out.1
11 = Block Out.2
12 = Block Out.3
13 = Block Out.4
14 = Block Out.5
15 = Block Out.6
16 = Block Out.7
17 = Block Out.8
18 = Block Out.9
19 = Block Out.10
0.00
184
0 = Forward
0
123
1 = Reverse
0 = Preset frequency 0
1 = Keypad
2 = Fieldbus
3 = AI1
4 = AI2
5 = AI1+AI2
6 = PID reference
7 = Motor potentiome-
ter
8 = Joystick
3 *
122
9 = Jogging reference
10 = Block Out.1
11 = Block Out.2
12 = Block Out.3
13 = Block Out.4
14 = Block Out.5
15 = Block Out.6
16 = Block Out.7
17 = Block Out.8
18 = Block Out.9
19 = Block Out.10