3.3 Detailed descriptions of each command

3.3.1 Error status

@ERR
Error status
Format
Only return value
Return value
@ERR, error
Parameter
error: Error status
Example
@IOS
@ERR,2
Remarks
1 = Erroneous parameter format or value
2 = Undefined command or wrong format
3 = Currently cannot be used.
4 = Not used.
5 = The command could not be executed, because the control command was not
registered.
6 = The command could not be processed since another command was being
executed.
7 = Automatic measurement of input timing failed.
8 = Loading EDID from the sink device failed.
9 = Not used.
10 = The control command was stopped according to the stop condition.
11 = The control command was stopped since the number of retries exceeded the
set value of "RETRY".
12 = The control command of PJLink was stopped since the password did not
match.
13 = The image could not be captured since the image size to be captured
exceeded the reserved memory size.
14 = Capturing input image failed.
MSD-501/502 Command Guide
Sending @IOS command
Command format error
17