Then
Then
Then set the trigger level using the numeric keypad, the ▲|▼ arrows, or the
Trigger Settings Annotation
Trigger settings are annotated on the FieldFox screen as highlighted in
following image:
Trig Level = -10 dBm, Trig Type (Int), Pos Slope (/), Delay
Pulse Timing Diagram
Marker Settings
Markers are not allowed with Meter-style measurements.
Markers are displayed on Tr 1 and also on the zoom trace if the marker is within
the zoom window time span.
Up to six standard markers can be used to provide readouts of the Y-axis
amplitude at the current X-axis location.
The six standard markers can also be used as Delta Markers.
Learn more about standard markers on page 174.
162
Trigger
Trig Level
rotary knob. A line appears on Tr 1 at the current trigger level setting. Data
acquisition occurs when the RF input signal crosses the line. This setting can
be used with either Positive or Negative edge triggering.
red
in the
FieldFox User's Guide