Analog Outputs - Parker 590+ DRV Product Manual

Table of Contents

Advertisement

ANALOG OUTPUTS

This function block converts the demand percentage into
0-10V, suitable for driving the analog output electronics of the drive.
10V CAL
INPUT
ANALOG OUTPUTS
Parameter
INPUT
Analog output value as a percentage of range.
10V CAL
(% TO GET 10V)
Scaler value which produces 10V output. Set 10V CAL to be 50% to get ±10V out for ±50% in.
OFFSET
Offset value added to the normal output value after the scaler and before the modulus.
MODULUS
Unipolar analog output enable. If TRUE, then -10% gives +1V out.
ANOUT 1 (A7) to ANOUT 2 (A8)
Actual voltage output to the terminal.
DC590+ DRV Series DC Digital Drive
OFFSET
X
X
MODULUS
Tag
678, 679
245, 248
464, 465
362, 363
55, 56
DIAGNOSTIC
D-23
Programming
Range
-300.00 to 300.00 %
-300.00 to 300.00 %
-100.00 to 100.00 %
FALSE / TRUE
⎯.xx V (h)

Hide quick links: