DIAGNOSTICS (MMI only)
Parameter
UNFIL.TACH INPUT
Analog tachogenerator feedback (unfiltered).
ENCODER
Encoder speed feedback in RPM.
UNFIL.ENCODER
Encoder speed feedback in RPM (unfiltered).
UNFIL.SPD.FBK
Unfiltered speed feedback.
UNFIL.SPD.ERROR
Unfiltered speed error.
CONTACTOR CLOSED
Main contactor control signal.
HEALTH LED
State of Health LED on Keypad.
READY
The drive is ready to accept an enable signal.
DRIVE RUNNING
Drive is enabled and may make current when TRUE. A diagnostic for those parameters
that can only be written to when the drive is stopped (parameters marked with Note 2 in
the Parameter Specification Table).
SYSTEM RESET
Set for one cycle as the drive is enabled.

SETUP PARAMETERS

Refer to Appendix D for parameter details. A parameter can be located by referring to the Parameter Specification Table: Tag Number Order.
The layout of this 590+ menu is shown by The Menu System Map on page 6-8.
DC590+ DRV Series DC Digital Drive
Tag
58
206
59
62
64
83
122
125
376
374
The Keypad
Range
SETUP PARAMETERS Function Blocks
⎯.x %
Refer to CALIBRATION
⎯. RPM
Refer to ENCODER
⎯. RPM
Refer to ENCODER
⎯.xx %
Refer to SPEED LOOP
⎯.xx %
Refer to SPEED LOOP
FALSE / TRUE
Refer to SEQUENCING
FALSE / TRUE
FALSE / TRUE
Refer to SEQUENCING
FALSE / TRUE
Refer to SEQUENCING
FALSE / TRUE
Refer to SEQUENCING
6-15
Refer to ALARMS