6-10
The Keypad

The Keypad Menus

DIAGNOSTICS
The DIAGNOSTICS Menu table describes all the parameters in the MMI's DIAGNOSTICS menu. These parameters are "read-only" and are very
useful for tracing configuration problems. The list is shown in MMI order, and the parameter names are as displayed by the 6901 Keypad and the DSE
Configuration Tool.
DIAGNOSTICS (MMI only)
Parameter
SPEED DEMAND
Speed loop total setpoint after the ramp-to-zero block.
SPEED FEEDBACK
Speed loop feedback.
SPEED ERROR FILT
Speed loop error.
SPEED LOOP O/P
Output from speed loop PI.
CURRENT DEMAND
Current loop demand
(speed error PI output or external current demand clamped by all the current limits).
CURRENT FEEDBACK
Scaled and filtered current feedback.
CURRENT FBK. AMPS
Scaled and filtered armature current in Amps.
IaFbk UNFILTERED
Scaled current feedback (unfiltered).
IaDmd UNFILTERED
Scaled current demand (unfiltered).
POS. I CLAMP
Positive current clamp.
NEG. I CLAMP
Negative current clamp.
Tag
89
207
297
356
299
298
538
65
66
87
88
Range
SETUP PARAMETERS Function Blocks
⎯.
%
XX
Refer to SPEED LOOP
⎯.
%
XX
Refer to FEEDBACKS
⎯.
%
XX
Refer to SPEED LOOP
⎯.
%
XX
Refer to SPEED LOOP
⎯.
%
XX
Refer to CURRENT LOOP
⎯.
%
XX
Refer to FEEDBACKS
⎯.
AMPS
XX
Refer to CURRENT LOOP
⎯.
%
XX
Refer to CURRENT LOOP
⎯.
%
XX
Refer to CURRENT LOOP
⎯.x % (h)
Refer to CURRENT LOOP
⎯.x % (h)
Refer to CURRENT LOOP