OP STATION

MMI Set-up options and Local setpoint information.
OP STATION
Parameter
LOCAL KEY ENABLE
Enables the LOCAL/REMOTE control key on the op-station. Set to TRUE to allow the operator to toggle between local and remote modes.
SETPOINT
SET UP menu - Actual value of local setpoint. This value is not persistent.
JOG SETPOINT
SET UP menu - Actual value of local jog setpoint. This value is not persistent.
RAMP ACCEL TIME
Acceleration time used while in Local mode.
RAMP DECEL TIME
Deceleration time used while in Local mode.
INITIAL DIR
START UP VALUES menu - Start-up mode of local direction on power-up. Set to TRUE for Forward.
INITIAL MODE
START UP VALUES menu - Start-up mode of Keypad LOCAL/REMOTE control key on power-up. Set to TRUE for Local mode.
INITIAL VIEW
START UP VALUES menu - Start-up mode of Keypad PROG key on power-up. Set to TRUE for Program mode to see the local setpoint.
DC590+ DRV Series DC Digital Drive
Tag
511
512
513
514
515
516
517
518
D-85
Programming
Range
FALSE / TRUE
0.00 to 100.00 %
0.00 to 100.00 %
0.1 to 600.0 s
0.1 to 600.0 s
REVERSE / FORWARD
REMOTE / LOCAL
LOCAL / PROGRAM