Emissions Limits - Parker 590+ DRV Product Manual

Table of Contents

Advertisement

EMC

Emissions Limits

Conducted
decreasing with log of frequency to:
Harmonics (Low Frequency Emissions)
I < 75A
I > 75A
Harmonic emissions for DC drive installations cannot be predicted here as they are determined by motor parameters that are installation dependent.
For help in determining the harmonics contact Parker SSD Drives.
Where these levels are too high and to ensure compatibility with other equipment, EMC filters are available from Parker SSD Drives.
Radiated
Where these levels are too high and to ensure compatibility with other equipment, Parker SSD Drives can advise on suitable counter-measures.
DC590+ DRV Series DC Digital Drive
Frequency (MHz)
where I ≤100A
0.15 - 0.5
0.5 - 5.0
5.0 - 30.0
where I ≥100A
0.15 - 0.5
0.5 - 5.0
5.0 - 30.0
61000-3-12
61000-3-4
Frequency (MHz)
30≤ f- ≤230
230≤ f- ≤1000
DB (μV)
Quasi Peak
Average
100
86
90
70
130
125
115
DB (μV)
Quasi Peak
50
60
Certification
Product Specific
EN 61800-3
90
76
80
Category C3
Table 17
60
120
115
105
Product Specific
EN 61800-3
Category C3
(Table 18)
Measured at 10m
B-11