The EI-BISYNCH Prime Set contains the EE mnemonic. This is also an output parameter in the MAIN PORT (P1), AUX
PORT (P2) and SYSTEM PORT (P3) function blocks, where the parameter value can be read and reset. Refer to the
COMMS Option Technical Manual for further details.
The parameter displays the last error as a hexadecimal code. The following values are returned if an enquiry (reading
information from the Drive) is performed on this Read/Write parameter.
Value
>00C0
>01C7
>02C2
>03C2
>04C8
>05C8
>07C7
>07C8
>08C8
Writing any value to this parameter will set the value to >00C0 (No Error). Clearing the last error value may be useful in seeing a repetitive error re-