[21]
IR COMPENSATION
BACK EMF
x
CURRENT FEEDBACK
SCALED
-
ARMATURE
x
BEMF FILTER
+
VOLTAGE
FEEDBACK
[20]
ARMATURE V CAL
TERMINAL VOLTS
DC590+ DRV Series DC Digital Drive
[177]
EMF GAIN
[191]
[176]
BEMF LEAD
EMF LAG
[175]
[192]
BEMF LAG
EMF LEAD
-
FIELD WEAKENING PID
+
WEAK PID OUT
[178]
[171]
MAX VOLTS
WEAK PID ERROR
[179]
MIN FIELD
-
+
FIELD DEMAND
[174]
FIELD SETPOINT
FIELD WEAK ENABLE
Programming
FIELD I CAL
SCALED FIELD
x
CURRENT FEEDBACK
[182]
FIELD I FEEDBACK
[210]
FIELD DEMAND
RATIO OUT/IN
[172]
INT. GAIN
[173]
PROP. GAIN
FIELD FIRING ANGLE
-
FIELD CURRENT PI
+
[209]
FIELD ENABLED
FIELD CONTROL MODE
KEY
Field Control Block Diagram
D-153
[170]
FIELD ENABLE
FIELD THYRISTOR
FIRING CONTROL
VALUE SET-UP PARAMETER
LOGIC SET-UP PARAMETER
VALUE DIAGNOSTIC
LOGIC DIAGNOSTIC
TAG NUMBER