Analog / Encoder (Plug X11); Analog / Encoder (Plug X11); Wiring Of The Analog Input; Wiring Of Analog Outputs - Parker Compax3 Series Operating Instructions Manual

Positioning via digital i/os
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Parker EME
3.1.9.

Analog / Encoder (plug X11)

3.1.9.1
3.1.9.2
PIN X11 Reference
High Density Sub D
1
+24V (output for encoder) max. 70mA
2
Reserved
3
D/A monitor channel 1 (±10V, 8-bit resolution)
4
D/A monitor channel 0 (±10V, 8-bit resolution)
5
+5V (output for encoder) max. 150mA
6
A/ (Encoder simulation)
7
A (Encoder simulation)
B (Encoder simulation)
8
9
Reserved
10
Reserved
11
Reserved
B/ (Encoder simulation)
12
13
N/ (Encoder simulation)
N (Encoder simulation)
14
15
GND

Wiring of the analog input

2.2K
10nF
10K
X11/9
Ain+
10K
Ain-
X11/11
10nF
2.2K

Wiring of analog outputs

332
+/-10V/1mA
(max: 3mA)
I11 T11 192-120101 N6 - March 2004
X11/4
X11/3
X11/15
Compax3 device description