Contactor Failed Procedure - Parker 590+ DRV Product Manual

Table of Contents

Advertisement

7-26
Trips and Fault Finding

Contactor Failed Procedure

This flowchart is used for troubleshooting problems associated with the main contactor, AM, including wiring. Refer to the schematic/wiring diagrams
in Chapter 3 when troubleshooting.
Is the main contactor
Is 120 VAC present at
energised?
Possible bad stack;
Is +10 VDC measured
Possible missing wire;
at terminal A5?
install jumper between
(Current Limit OK?)
terminals B3 and A6.
Is +24 VDC measured
Is wire from terminal
at terminal C5
C9 to Aux. contact
(Enable)?
terminal on contactor
Figure 7-4 Troubleshooting Flowchart for Faulty DC Contactor
Disconnect all
D5 and D6?
power!
Measure continuity of
replace stack.
wire from D5 to
contactor.
Measure continuity of
wire from D6 to
contactor.
Possible bad contact;
replace contactor.
Bad DRV Chassis
DC590+ DRV Series DC Digital Drive

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents