Keys For Operating The Drive Locally - Parker 590+ DRV Product Manual

Table of Contents

Advertisement

Keys for Operating the Drive Locally

FORWARD/
REVERSE
JOG
RUN
STOP/RESET
Indications
Keypad Alarm Messages
An alarm message will be displayed on the MMI when the unit is tripped.
The Drive has tripped.
The top line indicates a trip has occurred while the bottom line gives the reason for the trip. See
example opposite.
Acknowledge the trip message by pressing the E key. Press the STOP/RESET key to restore the Health
LED.
Refer to Chapter 7: "Trips and Fault Finding" for trip messages and reasons.
DC590+ DRV Series DC Digital Drive
Control
- Changes the direction of motor rotation when in Local mode, indicated by the display. Selects between
two jog speeds when in Jog mode. This key has no function in Remote mode.
Control
- Runs the motor at a speed determined by the JOG SPEED 1 parameter. When the key is released, the
Drive returns to "stopped". Only operates when the Drive is "stopped" and in Local mode. This key has no
function in Remote mode.
Control
- Runs the motor at a speed determined by the LOCAL SETPOINT.
Trip Reset
- Resets any trips and then runs the motor as above. Only operates when the Drive is in Local mode.
Control
- Stops the motor. Only operates when the Drive is in Local mode.
Trip Reset
- Resets any trips and clears displayed message if trip is no longer active.
6-3
The Keypad

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents