Emc Wiring Details - Parker 590+ DRV Product Manual

Table of Contents

Advertisement

3-6
Installing the Drive

EMC Wiring Details

Cabling Requirements
Cables are considered to be electrically sensitive, clean or noisy. You should already have planned your cable routes with respect to segregating these
cables for EMC compliance. If not, refer to Appendix B: "Certification".
If the drive is to be operating in a regenerating mode for extended periods acting as a load generator for another machine, it is advisable to fit
additional protection in the armature circuit. A dc fuse or high speed circuit breaker will provide this protection. If in doubt, contact Parker SSD
Drives.
fuse or suitable
circuit breaker
(RCD not
recommended)
signal/control cable
(sensitive)
Not fitted to
Frame H units
power
supply
external
cable
ac
contactor
filter
(optional)
(clean)
Figure 3-1 Cabling Requirements
(noisy)
590AC
Line Choke
choke
Filter
CO468398
DC590+ DRV Series DC Digital Drive
field cable
drive
(noisy)
motor
motor cable

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents