MIN SPEED

The Min Speed function block may be used to prevent the drive running with a zero setpoint.
MIN SPEED
Parameter
INPUT
Input value.
MIN SPEED
The minimum speed clamp is fully bi-directional and operates with a 0.5% hysterisis. If this parameter is less than 0.5% it is ignored and OUTPUT =
INPUT.
OUTPUT
Clamped value of input.
Tag
5
126
Minimum Speed
Output
Input
691
Range
-105.00 to 105.00 %
0.00 to 100.00 %
-0.5 0
0.5
⎯.
%
XX