Installing the Drive
Communications Technology
Options
Various protocols are supported, each requiring a different
Technology Box. The type of Technology Box fitted is selected in
the TYPE parameter:
• RS485 (EI BINARY, EI ASCII or MODBUS RTU)
• PROFIBUS DP
• LINK
• DEVICENET
• CANOPEN
• LONWORKS
COMMS Option Technology Box
The option allows the DC590+ DRV Drive to be controlled as part of a system.
The system can also comprise other Parker SSD Drives products such as the 605 and 584SV
Inverters, or any other equipment using the same protocol.
IMPORTANT : The comms option should not be fitted or removed whilst the product is
powered.
MMI Menu Map
1
SERIAL LINKS
2
TEC OPTION
TEC OPTION TYPE
Speed
Feedback
Comm s
Option
Option
COMMS
Speed
Option
Feedback
Option
Mounting
Main Serial Port (P1)
DC590+ DRV Series DC Digital Drive
Earthing